眼科 ›› 2015, Vol. 24 ›› Issue (2): 119-122.doi: 10. 13281/j. cnki. issn.1004-4469. 2015. 02. 011

• 论著 • 上一篇    下一篇

甲状腺相关眼病患者眼调节功能的初步研究

翟宁 王雪 王小兵 赵世强 邓秀静 曹琪玥 马芙蓉   

  1.  100730 首都医科大学附属北京同仁医院 北京同仁眼科中心 眼科学与视觉科学北京市重点实验室(翟宁、王小兵、赵世强、邓秀静、马芙蓉);北京同仁医院内分泌科(王雪、曹琪玥)
  • 收稿日期:2014-06-08 出版日期:2015-03-25 发布日期:2015-04-06
  • 通讯作者: 王小兵, Email: littlebill@sina.cn
  • 基金资助:

    北京市卫生系统高层次卫生技术人才基金( 2011-3046);国家自然科学基金面上项目( 10772124);国家自然科学基金重点项目( 11232013)

Preliminary research on the accommodative function in patients with thyroid associated ophthalmopathy

ZHAI Ning1, WANG Xue2, WANG Xiao-bing1, ZHAO Shi-qiang1, DENG Xiu-jing1, CAO Qi-yue2, MA Fu-rong1   

  1. 1. Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, Beijing 100730, China; 2. Department of Endocrinology, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
  • Received:2014-06-08 Online:2015-03-25 Published:2015-04-06
  • Contact: WANG Xiao-bing, Email: littlebill@sina.cn

摘要: 目的 探讨甲状腺相关眼病(TAO)对眼调节功能的影响。设计 前瞻性病例系列。研究对象  TAO患者 25例,男性 8例,女性 17例,年龄 18~40岁,平均(31.0± 6.2)岁。选取相同年龄段和屈光度范围的正常人 20例为对照组。方法 对患者及正常对照组行显然验光、主观调节幅度检查,使用 Nidek AA-1人眼调节分析仪客观检测眼调节功能。主要指标 调节幅度、调节反应量。结果  TAO患者调节幅度(+5.42± 1.97 D)比对照组(+6.54± 1.66 D)低(t=-2.88,P=0.005)。调节功能客观检查显示17例(68%)患者存在调节功能异常,其中11例(44%)调节不足,4例(16%)调节不足伴调节紧张,2例(8%)调节紧张。结论 TAO可引起眼调节功能的异常,其异常类型以调节不足为主。(眼科, 2015, 24: 119-122)

关键词: 甲状腺相关眼病, 睫状肌, 调节功能

Abstract: Objective To explore the influences of thyroid associated ophthalmopathy (TAO) on the accommodative function of human eye. Design Prosprective case series. Participants 25 patients with TAO and 20 age and refraction matched healthy controls. The average age of the patients was 31.0±6.2 years old (18~40 years). Methods Direct refraction and subjective accommodative amplitude test were performed for all the participants. Objective measurement of accommodative function was examined using the Nidek AA-1 accommodative analyzer. Main Outcome Measures Accommodative amplitude, accommodative response. Results In the subjective accommodative amplitude test, the accommodation amplitude of TAO patients (+5.42±1.97 D) was lower than that of the controls (+6.54±1.66 D) (t=-2.88,P=0.005). In the objective accommodative function test, accommodative dysfunction happened in 17 cases (68%), including 11 cases (44%) with accommodative lag; 4 cases (16%) with accommodative lag combined with accommodative strain, and 3 cases (8%) with accommodative strain. Conclusion TAO can cause accommodative dysfunction, in which accommodative lag is most common. (Ophthalmol CHN, 2015, 24: 119-122)

Key words: thyroid associated ophthalmopathy, ciliary muscle, accommodative function